Rel-Easy OM4 Duplex Fiber Optic Patch Cord PVC 1M
SPAEMJAIFIF001205001
OM4 Duplex LC Fiber Patch Cord
The Rel-Easy OM4 fiber optic patch cord LOMMF (laser optimized multi-mode fiber) can easily cope with high-density cabling. It's easy to remove the OM4 duplex LC patch cord by using the patented tab. The zirconia ceramic ferrule can ensure stable signal transmission and the best insertion loss and return loss, making the network installation more secure.
The multimode fiber cable complies with ITU-T G.651.1, TIA/EIA 492AAAD, and IEC60793-2-10 standards, and complies with all RoHS environmental regulations. OM4 LOMMF connects to 10GBase-SR in education, enterprise, government, healthcare, finance, and commercial industries, and data centers.
The use of OM4 fiber cabling can ensure fast transmission, high reliability, and can reduce maintenance costs. And provide better network signals, contact us for more product information.
The OM4 Fiber Optic Support 10G / 25G / 40G / 100G Application
- 10G Ethernet speed up to 400m at 850nm (10Gbase-SR)
- 25G Ethernet speed up to 100m at 850nm (25Gbase-SR)
- 40G Ethernet speed up to 350m at 850nm (40Gbase-SWDM4)
- 100G Ethernet speed up to 100m at 850nm (100Gbase-SWDM4)
Product Classification
Indoor or Outdoor | Indoor, Outdoor |
---|---|
Solution | Fiber |
Product Name | Fiber Patch Cord |
General Specifications
Item model number | SPAEMJAIFIF001205001 |
---|---|
Color | Violet |
Length(M) | 1 |
Connector Type | LC |
Material Specifications
Jacket | PVC |
---|---|
Material | Zirconia, PC, PVC |
Fiber Mode | OM4 |
Fiber Count | 2 |
Insertion Loss | <0.3dB |
Return Loss | >35dB |
Polish Type | PC |
Cable Diameter | 3.0mm |
Polarity | A(Tx) to B(Rx) |
- Related Products
Rel-Easy OM4 Duplex Fiber Optic Patch Cord PVC 2M
SPAEMJAIFIF002205001
The Rel-Easy OM4 fiber optic patch cord LOMMF (laser optimized multi-mode fiber) can easily cope with high-density cabling. It's easy to remove the OM4 duplex LC patch cord by using the patented tab. The zirconia ceramic ferrule can ensure stable signal transmission and the best insertion loss and return loss, making the network installation more secure.The multimode fiber cable complies with ITU-T G.651.1, TIA/EIA 492AAAD, and IEC60793-2-10 standards, and complies with all RoHS environmental regulations. OM4 LOMMF connects to 10GBase-SR in education, enterprise, government, healthcare, finance, and commercial industries, and data centers.The use of OM4 fiber cabling can ensure fast transmission, high reliability, and can reduce maintenance costs. And provide better network signals, contact us for more product information.
- Download
Specification-Fiber Patch Cord Solution-LC Rel-Easy
LC Rel-Easy Fiber Optic Patch Cords Specification in SM and OM3, OM4, OM5
(User Guide) Rel-Easy Patch Cord
For Long Latch Rel-Easy Fiber Patch Cord to quick installation instruction
- Additional Info
The Difference of Single-Mode (SM) and Multi-Mode (MM) Fiber
- The core diameter of single-mode fiber is much smaller than multimode fiber, the single-mode fiber core diameter is 9µm; the single-mode fiber wavelength is 1310 nm and 1550 nm.
- Multimode fiber core diameter: 50µm or 62.5µm. 850nm and 1300nm wavelengths are used in multimode fiber cables.
Transmission distance is the key to choosing single-mode or multi-mode fiber, for data centers, multi-mode fiber optic cables are sufficient to meet the distance of 300 - 400 meters. In applications that require distances of up to several kilometers, single-mode fiber is the best choice.
Fiber Path Cord Polish Matters
The light loss will occur when a connector is installed, yet some will cause damage to laser light and disrupt the transmitted signal. Choosing the well polish connector will reduce the back reflections of light.
- PC: Physical Contact polish with -35dB Return Loss measurement
- UPC: Ultra Physical Contact polish with -55dB Return Loss measurement
- APC: Angled Physical Contact polish (8-degree angle) with -60dB Return Loss measurement
Can I mix single-mode and multi-mode fiber?
The core sizes of multimode fiber and single-mode fiber are different, and the transmitted light mode is also different. If two optical fibers are mixed or directly connected together, a large amount of optical loss will be lost, resulting in link jitter or disconnection. Remember, never mix different types of cables randomly.