UL listed PVC CM Rated 23 AWG Ethernet Cat.6A F/UTP Solid Data Lan Cable 305M
6A-FT-OR-0305-03-00
Cat6a Stp Cable
CRXCabling CM Rated Cat.6A FUTP Lan Cable has a higher bandwidth of up to 500 MHz, meets electrical transmission ISO/IEC 11801-1 and IEC 61156-5 (Edition 2.1). CM jacket fire resistance rating defined in UL 1685, pass a standardized flammability test before used.
Cat.6A STP RJ45 keystone jack (Model number: A04-6ASB4018) provides speeds up to 10Gbps in a 100-meter with Cat6A shielded Ethernet cable. Also we offer a straight type or V-type panel to achieve the best installation effect. It is recommended to use it in a data center to get good network performance.
Choosing 23AWG wire to prepare for wider and more advanced PoE applications in the future! With less heat generation, 23AWG LAN cable will provide a stable transmission performance to structured cabling. Plan wisely for the next decades.
CRXCabling provides complete Cat.6A permanent link products, which can establish a faster and better network experience, and all series of products have a 25-year product warranty.
Features
- Structure cabling for horizontal and building backbone cable.
- Metal shielded and braided providing good protection from EMI noise.
- IEEE 802.3af (PoE) / IEEE 802.3at (PoE+).
- High performance of transmission, sweep frequency up to 500 MHz.
- CM rated cable meets UL 1685 standard with PVC jacket, RoHS compliant.
Product Classification
Indoor or Outdoor | Indoor |
---|---|
Solution | Copper |
Product Name | Lan Cable |
Component Category | Cat.6A |
General Specifications
Item model number | 6A-FT-OR-0305-03-00 |
---|---|
Color | Orange |
Shielded Type | Shielded |
Length(M) | 305 |
Material Specifications
Jacket | PVC |
---|---|
Material | Conductor: Bare Copper |
Wire Gauge | 23 |
Cable Type | F/UTP |
Cable Diameter | 7.70 ± 0.2 mm |
- Related Products
Indoor PVC CM Rated 23AWG S/FTP Cat.7A Solid Data Lan Cable 305M
7A-SS-WH-0305-03-00
Cat.7A 23AWG Easy to Pull Lan Cables are suitable for in-wall installation, residence, or a single-story commercial building. CM jacket fire resistance rating defined in UL 1685, pass a standardized flammability test before used. It has a higher bandwidth of up to 1000MHz, meets electrical transmission ISO/IEC 11801-1 and IEC 61156-5 (Edition 2.1). This cable offers extensive shielding to reduce signal attenuation and is relatively stiff in comparison to previous generations of cabling. It is great for datacenters, server rooms, and telecommunications rooms.CRXCabling professional team is always at your disposal, we're pleased to introduce our solutions that meet your requirements.
UL Listed Solid Cat.6A STP RJ45 Connector For 1.2 mm In Gold Color
A01-6A88S1019
RJ45 Connector can support long-distance power over Ethernet applications. It is mainly used in 10G or 10G+ Ethernet Network for Cat.6A/ Cat.7 larger cable.The Cat.6A STP RJ45 Plug can fit in 1.2mm, 23 - 26AWG solid wire, featured in the swallow-tail design which can hold the cable tightly and provide good ground bonding. We highly recommend RJ45 Boot For Larger Cable (model no:A02-0030800GY) to work with connector so that it will not tripped when unplugging other patch cords.To make sure the good performance with unique design, it compliant with multiple registrations, such as FCC standard, ANSI/TIA-568-D, PoE Plus, REACH and RoHS.CRXCabling aims to help enterprises with an easy-to-manage LAN system, contact our professional team to obtain a tailor-made wiring plan now!
- Download
Specification-Data LAN Cable-Cat.6A FUTP PVC Jacket
Data LAN Cable-Cat.6A FUTP PVC Jacket Specification
Data Sheet-CM Rated 23AWG Cat.6A F/UTP Solid Lan Cable
CM Rated 23AWG Cat.6A F/UTP Solid Lan Cable Data Sheet.
- Related Blog
The Twisted Pair Cable: The Basics of Understanding What It Is And How it Works.
Twisted pair cables are a type of transmission medium that can be used to transmit both digital and analog signals. It is one of the most popular types of cables in use today.The twisted pair cable is made up of two insulated copper wires that are twisted together to reduce electromagnetic interference (EMI). The twisting also helps to keep the wires separated so that they do not touch each other and cause a short circuit.
- Additional Info
Solid: Also called single-strand wire, consists of one piece of metal wire, and generally used for in-wall wiring.
Stranded: Composed of small-gauge wires to make a larger conductor and more flexible.
PVC: Made of polyvinyl chloride jacket, commonly used for horizontal runs from the wiring center.
LSZH: Low smoke zero halogen has a flame-resistant jacket that doesn't emit toxic fumes even if it burns.
CM: The 'M' in CM is for 'Multipurpose'. CM rated cable general use in where the fire code does not place any restrictions on cable type and suitable for in-wall installation.
CMR: The 'R' in CMR is for 'Riser'. CMR rated cables are aimed to prevent the spread of fire from floor to floor and are suitable for vertical shaft applications.
CMP: The 'P' in CMP is for 'Plenum'. CMP rated cables are suitable for installation in ducts and plenums without the use of conduit. These cables are designed for fire resistance and low-smoke and toxin producing characteristics.
CMX: The 'X' in CMX is for 'Outside Plant'. CMX rated cables are suitable for installation in outdoor applications where exposed to the elements, resisted the UV retardant.
Solution Provider of Telecom
Developing future-oriented products that meet high standard of needs; offering versatile end-to-end copper and fiber cabling solutions to increase business success around the globe.
Advantage
High-Quality is Our Policy Ensure the quality and safety of goods. Acquire telecom insights to stay in front of trends. Regulate and provide series cabling solution service. Read More