UL Listed Ultra-Slim Scorpion Cat.6A STP 30AWG Patch Cord With Color Clips PVC 1M
6A-SS-01-BK-0100-09
UL Verified PVC 4PR/30 Cat.6a Shielded RJ45 Ethernet Cable, Black Color
Revolution to your cabling solution, the Ultra-Slim Scorpion 30AWG Patch Cord is the ideal solution for high-density cabling systems. With changeable scorpion color clips design, it enables the convenience of identification and also has seven colors for choices to label different applications. Designed to meet the ANSI / TIA-568.2-D and ISO / IEC 11801 standards, and support Cat.6A networks running up to 500 MHz applications. UL listed Cat.6A STP RJ45 Patch Cord is also consisted of 100% bare copper wires.
By using 50-micron gold-plated contacts to provide superior conductivity. The RJ45 modular pug is designed for an insertion and extraction life of 750 cycles, making for an ultra-reliable solution that you can count on to perform.
Structured cabling can connect different types of equipment arbitrarily, and it can also support any standard-compliant network products and support various network structures. CRXCabling provides complete products and services, please contact our specialists for more information.
Features
- Meet ANSI/TIA-568.2-D and ISO/IEC 11801 standards.
- Cable tested to exceed Cat.6A industry standard of 500 MHz.
- UL listed cabling to ensure its quality.
- RJ45 gold-plated 50 U" contacts. For 750 mating cycles to provide superior conductivity.
- Perfect solution for 10BASE-T, 100BASE-TX (Fast Ethernet), 1000BASE-T (Gigabit Ethernet) and other high-speed applications.
Product Classification
Indoor or Outdoor | Indoor |
---|---|
Solution | Copper |
Product Name | Patch Cord |
Component Category | Cat.6A |
General Specifications
Item model number | 6A-SS-01-BK-0100-09 |
---|---|
Color | Black |
Shielded Type | Shielded |
Length(M) | 1 |
Connector Type | RJ45 |
Material Specifications
Jacket | PVC |
---|---|
Material | Conductor: Bare Copper |
Coating of the Contacts | Gold 50U" |
Wire Gauge | 30 |
Cable Type | S/FTP |
- Movies
- Related Products
1U Cat.6A FTP 90 Degree Network Patch Panel
CC-07-00023
CRXCabling's 90-degree FTP Cat.6a patch panel 24 port is designed to provide easy installation, connecting the Cat.6a patch cord and cat6a lan cable in cabling. It supports the 110 IDC and Krone punch down tool, the IDC module of the network panel has color-coded labels for T568A and T568B wiring schemes, and a rear cable management frame can be used to fix the cat6a ethernet cable. The screened Cat.6a ethernet patch panel is an ideal choice for network applications to supports fast Ethernet communication, conform to ANSI/EIA/TIA 568.2-D and ISO/IEC 11801 standards, and can be installed in a 19" cabinet, 2-post rack, and the wall-mount rack enclosure.CRXCabling provides a complete product line in cat6a wiring, which is recommended for use in data centers or commercial structured cabling with excellent and fast network experience. With a 25-year channel link warranty, allowing you to enjoy peace of mind when making the purchase, contact our sales team to get more information. p
4PPoE FTP Tool-free Shuttered Cat.6A keystone RJ45
A04-6ASB4018
Run PoE safely on keystone jack! The 180-degree tool-free design cat6a keystone is fully shielded which can prevent EMI/RFI and achieve a more stable connection in cat6a wiring. The wire covers facilitate wire separation with clear T568A and T568B wiring schemes, easy to install. Using the side buckle to fix the wire firmly during installation, it will make the connection stable and steady. Pressing tools (Model number: CC-15-00036) are recommended if users have batch installations to do.The shielded Cat6A jack provides speed up to 10Gbps over a 100-meter with Cat6A shielded ethernet cable. We recommend using these keystone jacks together with a network panel. It can be used with a straight type or V-type panel to achieve the best installation effect. It is recommended to use it in a data center to get good network performance.With CRXCabling cabling products, you can rest assured that your connection is reliable and secure over time, contact our professional team for the cabling advices.
UL Listed 180 Degree Cat.6A STP RJ45 Coupler
CC-05-00004
The Cat 6A STP RJ45 coupler is used for transmitting signals between point A and point B. Connecting two RJ45 patch cords into one and extending their length is the purpose of the CRXCabling Cat.6A STP RJ45 Coupler. According to the TIA/EIA 568.2-D standard, it meets Cat.6A performance requirements. The Ethernet transmission has high related to gold contact, our 50U" gold plating thickness is tested by X-ray machine to make sure its performance.The 8P8C female to female coupler jack is compatible with Cat6A, Cat6, Cat5e, Cat5 network. No termination needed with this straight snap-in type Cat.6A RJ45 coupler. From the server room/closet to any room in your home or office where network connectivity is desired. Our guarantee is to provide high-quality RJ45 Coupler and let our brand to add more value to your business.
- Download
Data Sheet-UL Listed Ultra-Slim Scorpion Cat.6A STP 30AWG Patch Cord With Color Clips
UL Listed Ultra-Slim Scorpion Cat.6A STP 30AWG Patch Cord With Color Clips Data Sheet.
- Related Blog
Testing Your Patch Cord Performance Before Plug-in, a Smart Way to Reduce the Risk of Your Network.
Patch cords play an important role in cabling systems and data centers, providing flexibility for moves and changes to the network. To ensure their function and speed transmission work in real field network cabling, having test program is a typical procedure to check. Therefore, there are two different ways to examine the patch cord performance: Channel Test and Component Test.
- Additional Info
RJ45: An eight-pin connector which widely used in Ethernet cable applications, is a standardized interface. With 8 position/8 blade contact, called an 8P8C, is a modular plug for telecommunication cables.
U/UTP: Unshielded twisted pairs, referred to UTP. It's the most common cable construction, consisting of no shielding twisted wires to create balanced transmission line.
F/UTP: Foiled with unshielded twisted pair, referred to FTP. It's featured in an overall foil shield wrapped around unshielded twisted pairs.
S/FTP: Shielded with foiled twisted pair, referred to PiMF or S/STP. The twisted pairs are wrapped in a foil tape before being wrapped in an overall flexible braid screen.
Solution Provider of Telecom
Developing future-oriented products that meet high standard of needs; offering versatile end-to-end copper and fiber cabling solutions to increase business success around the globe.
Advantage
High-Quality is Our Policy Ensure the quality and safety of goods. Acquire telecom insights to stay in front of trends. Regulate and provide series cabling solution service. Read More